Need information ?Contact us
.
Do you need more information
The BACT/ALERT® 3D Dual-T apparatus was designed for users who need to perform rapid and easy product control. Performing non-destructive, dual-temperature microbial detection, this alternative system offers its users the most reliable results.
The BACT/ALERT® Dual-T apparatus represents the automation of a traditional method : after injecting culture media bottles with a given sample, users only need to load the bottles into their system. Both the incubation and reading phases are automatically and objectively performed :
Designed with our own patented colorimetric technology, this growth-based system can detect within 24-72 hours an extremely large range of organisms, such as aerobic, anaerobic, facultative microorganisms, yeast and fungi.
The dual-temperature feature of this system guarantees a complete coverage of growth conditions – and is compliant with the different pharmacopoeias - allowing to conduct microbial detection at both 32.5°C and 22.5°C.
To ensure accurate results’ traceability, we provide you with a 21 CFR Part 11-compliant data management system. Depending on your microbial testing needs, we offer the possibility to choose the most appropriate system among three different options : Signature, Select and Select Link.
bioMérieux also offers a wide range of BACT-ALERT® 3D Dual-T culture media bottles, adapted to the type of microbial detection performed.
To help you switch from a traditional 14-day testing method to an alternative automated system, bioMérieux will provide with the BACT/ALERT® 3D Dual-T Implementation Guide (BIG), containing the following:
- Installation Qualification (IQ) protocol
- Operational Qualification (OQ) protocol
- Performance Qualification (PQ) protocol
100/120 Volts (50-60 Hz)
220/240 Volts (50-60 Hz)
At 115 V.A.C.: Controller: 72 Watts typical; Incubator: 640 Watts typical; Low Temperature Cart: 660 Watts typical
At 230 V.A.C.: Controller: 72 Watts typical; Incubator: 640 Watts typical; Low Temperature Cart: 605 Watts typical
Controller: 245 BTU/hr, 2840 maximum
Incubator: 904 BTU/hr, 2840 maximum
Low Temperature Cart: 2249 BTU/hr at 660 watts
Low Temperature Cart: 2061 BTU/hr at 605 watts
Width: 35.6 cm (14 in)
Height: 91.4 cm (36 in)
Depth: 61.7 cm (24.3 in)
Weight: 57.2 kg (126 lbs)
Width: 49.6 cm (19.5 in)
Weight unloaded: 118.8 kg (262 lbs)
Weight loaded: 133.8 kg (295 lbs)
Width: 80.9 cm (31.9 in)
Height: 184.6 cm (72.7 in)
Depth: 66.1 cm (26.0 in)
Weight unloaded: 293.5 kg (647 lbs)
Weight loaded: 313.9 kg (692 lbs)
Width: 99.1 cm (39 in)
Height: 85.1 cm (33.5 in)
Depth: 63.5 cm (25 in)
Weight: 100 kg (220 lbs)
Storage: 20-85% relative humidity, non-condensing
Operating: 20-60% relative humidity, non-condensing
6562 feet (2000 meters)
BACT/ALERT® 3D microbial detection system
Please consult our local company or representatives for the availability of these products in your country
Easier contamination detection Improved ease of use Fewer fa...
Extreme sensitivity Extreme speed Simple process
Calibrated microbial reference No preparation time Easy to u...
High quality Wide range of media Reliable